Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
ImplantNews ; 11(6a): 169-173, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-733629

ABSTRACT

Objetivo: avaliar o limite de resistência de dois diferentes sistemas de grip interno e ligas de titânio para identificar possíveis situações de risco. Material e métodos: foram usados quatro grupos (dez unidades cada), da seguinte forma: 1) implantes de conexão hexagonal externa e liga de titânio grau 4; 2) implantes de conexão hexagonal externa e liga de titânio grau 5; 3) implantes de conexão hexagonal interna e liga de titânio grau 4; 4) implantes de conexão hexagonal interna e liga de titânio grau 5. Chaves de inserção descartáveis foram usadas, e cada conjunto foi submetido ao teste de torção (ASTM F543: 2007) para verificação do torque máximo e valor angular de ruptura. Resultados: os valores médios de torção em cada grupo foram: 203,43 Ncm, 172,65 Ncm, 217,85 Ncm e 181,60 Ncm, respectivamente. Os conjuntos constituídos de liga F67 (grau 4) e conexão morse mostraram maior resistência (teste Anova, p < 0,05). Os valores angulares médios de ruptura foram: 65,76°, 42,18°, 46,30° e 50,52°, respectivamente. Conclusão: os limites de resistência ao torque foram superiores à demanda clínica, o que induz ao raciocínio de que os sistemas são seguros para uso clínico, respeitando seus limites mecânicos. Contudo, o torque excessivo deve ser evitado, em vista do risco de deformação da conexão.


Subject(s)
Dental Implantation, Endosseous , Titanium
2.
Rev. dental press periodontia implantol ; 2(2): 80-90, abr.-jun. 2008. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-605482

ABSTRACT

O emprego de fixações zigomáticas e implantes convencionais em sistema de carga imediata para reabilitações de maxilas atróficas constitui alternativa recente e vem sendo amplamente descrito na literatura científica, assim como a busca constante pela otimização de índices de sucesso dos implantes. Neste trabalho, procurar-se-á verificar o índice de sobrevida destas fixações, além de verificar o comportamento das FZs em procedimentos de dois estágios e carga imediata, fazendo um estudo retrospectivo de longo prazo, utilizando uma amostra mais representativa. Para este estudo, avaliou-se 59 prontuários de pacientes submetidos a reabilitações maxilares através da instalação de fixações zigomáticas e convencionais, atendidos no período de janeiro de 2000 a dezembro de 2006. Os dados foram registrados por meio de uma ficha cadastral especialmente desenvolvida para este estudo, quantificados e correlacionados. Verificou-se o emprego de 151 FZs e 187 implantes convencionais instalados, sendo 57,63% dos casos com protocolo de duas FZs associadas a quatro implantes convencionais, em sistema de carga imediata. O índice de sucesso foi de 95,36% para as FZs submetidas à carga imediata ou em duas fases cirúrgicas.


The application of zygomatic fixations and conventional implants in a immediate loading system for rehabilitation in atrophic upper jaws consists on a recent alternative and it's being widely described on scientific literature, as well as the constant search of success indexes optimization on implants. On this work, it will be aimed to verify the index of permanence of these fixations, besides verifying the comportment of ZFs in two stages and immediate loading procedures, making a long term retrospective study, using a more representative sample. For this study, 59 handbooks of patients submitted to upper jaw rehabilitations were evaluated, through the installation of zygomatic and conventional fixations. They were attended on the period of January. 2000 to December, 2006. The data were registered through a chart, specially made for this study, quantified and correlated. It could be verified the application of 1 51 ZFs and 187 installed conventional implants, being 57.63% of cases as protocol of two ZFs, associated to four conventionai implants in immediate loading system. The index of success was 95.36% to the ZFs submitted to immediate loading or in two surgical phases.


Subject(s)
Humans , Male , Female , Immediate Dental Implant Loading , Mouth Rehabilitation , Maxilla/abnormalities , Maxilla/surgery , Jaw Fixation Techniques , Zygoma
3.
Rev. Salusvita (Online) ; 26(2): 101-108, 2007. ilus
Article in Portuguese | LILACS | ID: lil-559725

ABSTRACT

A etiologia da Alopécia Areata é multifatorial, porém apresenta-se com algumas controvérsias e sem o conhecimento claro dos fatores determinantes para o seu aparecimento. A correlação existente entre este tipo de enfermidade e as alterações presentes na cavidade bucal, com especial ênfase em focos de infecções e dentes inclusos, ainda se encontra sem comprovação científica, sendo raros os seus relatos na literatura. Os autores relatam um caso clínico, onde estas alterações foram relacionadas com a Alopécia Areata.


Alopecia Areata’s etiology is multifactorial; however there is some controversy and the determining factors for its manifestation are not known. The existing correlation between this type of infirmity and the alterations present in the buccal cavity, with special emphasis on infection foci and impacted teeth, have still not been scientifically proven, and reports on them in the literature are rare. The authors report a clinical case where these alterations were related to Alopecia Areata.


Subject(s)
Humans , Female , Adult , Tooth, Unerupted , Alopecia/etiology , Dentistry
4.
ImplantNews ; 1(6): 489-496, nov.-dez. 2004. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-415659

ABSTRACT

A estabilidade inicial vem sendo citada como importante fator de sucesso de reabilitação protética ancorada sobre implantes osseointegrados, em sistema de carga imediata. Analisando a estreita relação entre a definição de estabilidade dos implantes e o método de fresagem, imaginou-se uma relação entre os dados oferecidos pelo Osstell® e a força de resistência ao torque de inserção, que o motor de implante OsseoCare® oferece. Neste estudo verificou-se a inter-relação entre os valores obtidos pelos dois métodos em protocolos inferiores. Da análise dos resultados pôde-se depreender que existe uma correlação negativa entre os métodos. Apesar do resultado, ambos indicaram parâmetros elevados de estabilidade, ficando as diferenças possivelmente relacionadas a detalhes cirúrgicos


Subject(s)
Dental Implantation, Endosseous , Osseointegration , Dental Materials , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL